Sinjal ta' Ħruġ tad-Dawl ta' Emerġenza tal-AmazonCommercial, Pakkett 1, Combo tal-Ħruġ b'Battery Backup, 2 Irjus Aġġustabbli LED

Brand:AmazonCommercial

3.7/5

Ditta tal-Amazon

Jopera f'kundizzjonijiet niedja, iżda mhux imxarrba, u niexfa; temperatura operattiva 0-40 grad Celsius. Ċertifikat UL bi klassifikazzjoni tal-fjammi UL-94-5VA flimkien ma 'piż żejjed u protezzjoni żejda. Il-batterija tan-nikil-kadmju tipprovdi enerġija ta 'backup ta' 90 minuta fil-każ ta 'qtugħ tad-dawl; 1.2V 1000mAh. Dawl LED Epstar SMD fit-tul; Ħin tal-iċċarġjar 24 siegħa, ħin tal-iskarigu 90 minuta. Il-ħajt, is-saqaf, u l-immuntar fit-tarf; Vultaġġ ta 'Input: 120/277V; Konsum ta 'enerġija: 3.5W max; Output: 4W max. Sinjal LED ta 'ħruġ ta' emerġenza b'2 irjus aġġustabbli f'akkomodazzjoni ABS termoplastika, iffurmata bl-injezzjoni, ritardant tan-nar.
Brand AmazonCommercial
Country of Origin China
Item model number CR-7082R
Light fixture form Ceiling
Manufacturer AmazonCommercial
Material Acrylonitrile Butadiene Styrene
Power Source Battery Powered
Product Dimensions 19.7 x 3.6 x 7.2 inches; 2.6 Pounds
Style Modern

3.7

8 Review
5 Star
81
4 Star
10
3 Star
3
2 Star
0
1 Star
5

Ikteb ir-reviżjoni tiegħek

L-email tiegħek mhux se tiġi ppubblikata. L-oqsma obbligatorji kollha huma mmarkati bi*

Scritto da: Larry L. Davis
Revised - Emergency Lights Stay On
As an electrician, I want to install the lights and keep moving. 3 of 4 units, the emergency lights stayed on when power was applied. Initially, I though it was an installation error. But I double checked my work. Installed a few more and found 1 of 4 that worked. Ok, I discovered the issue. And it was an installation error. The lights have a back and front cover that snaps in place. I was wall mounting the fixtures so I just took off the back cover. The problem is there are multiple places to plug in the battery. But the right place is labeled BAT and you can't really access that plug very well if you just have the back cover off. And it is difficult the see the labeling. So take the front cover off and be sure to plug the battery into the terminal labeled BAT.
Scritto da: mark robatin
good price
a great replacement
Scritto da: 8Ntractorguy
No replacement bulbs
I should have researched better. No replacement bulbs as a more expensive unit would have. LEDs so may not have to worry about that. Time will tell.
Scritto da: Randy Fry
Thought they were Malfunctioning turns out battery plugged into wrong terminal.
If the lights stay on constantly then this is the problem.
Scritto da: John A Holland
Pass city code requirements
Liked
Scritto da: PJD
Easy to install.
I replaced a old one and was very easy to install. It didn’t look to difficult to put up without doing a replacement.
Scritto da: Peter D Bland
Church installation of multiple units
Cheaper to replace with all LED than to service old incandescent units
Scritto da: sunil patel
Good product
By it again

Prodotti relatati

hot
3.7/5

3.7/5

Skopri n-netwerk internazzjonali tagħna

Nibgħatu lejn 28 pajjiż, aktar minn 200,000 prodott. Ibqa' aġġornat, abbona man-newsletter.

Array